摘要: |
测定了在3.5%食盐水中碳钢的法拉第交流阻抗,其结果与理论解析结果一致。阴极保护的实际效率(保护效率p和保护电流利用率q的乘积即r=p×q)在腐蚀电位E′cor附近表现出最大值,这个电位可以认为是阴极保护的最佳保护电位。由于法拉第交流阻抗值容易被测得,为此提出了一种对阴极保护系统进行监测管理的一种新方法。 |
关键词: 阴极保护 碳钢 交流阻抗 防蚀电位 |
DOI: |
分类号: |
基金项目:中国科学院海洋研究所调查研究报告第2182号。赴日合作研究项目 |
附件 |
|
THE IMPEDANCE AND OPTIMUM PROTECTION WHEN CARBON STEEL PROTECTED CATHODICALLY |
Hou Baorong1, Atsushi Nishikata2, Tooru Tsuru2, Shiro Haruyama2
|
1.Institute of Oceanology, Academia Sinica, Qingdao 266071;2.Faculty of Engineering, Tokyo Institute of Technology
|
Abstract: |
The measured Faraday impedance of carbon steel in 3.5% NaCl solution, agreed with the theoretical. Marimum cathodic protection effecience (r) (protection effeciency p and utilization ratio of protection current q, r=p×q) is realized at around the corrosion potenntial E′cor, which can be regarded as the Optimum protection potential. As the Faraday impedance can be easily measured, a new method for assessingand setting up cathodic protection is possible. |
Key words: Cathodic protection, Carbon steel, Impedance, Corrosion potential |