首页 | 期刊简介 | 编委会 | 投稿指南 | 常用下载 | 联系我们 | 期刊订阅 | In English
引用本文:张晓君,白雪松,毕可然,许加涛,秦 蕾,阎斌伦.泥鳅(Misgurnus anguillicaudatus)病原霍乱弧菌(Vibrio cholerae)PCR 与LAMP检测方法的比较研究.海洋与湖沼,2013,44(1):209-214.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  下载PDF阅读器  关闭
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 2386次   下载 2488 本文二维码信息
码上扫一扫!
分享到: 微信 更多
泥鳅(Misgurnus anguillicaudatus)病原霍乱弧菌(Vibrio cholerae)PCR 与LAMP检测方法的比较研究
张晓君, 白雪松, 毕可然, 许加涛, 秦 蕾, 阎斌伦
淮海工学院海洋学院 江苏省海洋生物技术重点实验室
摘要:
采用分子生物学方法, 以霍乱弧菌lolB 为靶基因设计特异性引物, 进行了霍乱弧菌的PCR和环介导等温核酸扩增(Loop-mediated isothermal amplification, LAMP)检测技术研究, 并对它们的特异性、灵敏性和实际应用进行了比较。结果表明, 所建立的PCR 检测霍乱弧菌的方法最低检测限为4.0×103CFU/ml; LAMP检测方法在65℃下恒温扩增60min, 检测限为4.0×101CFU/ml, 反应产物加入荧光染料SYBR Green I后反应液呈现明显的绿色; 以温和气单胞菌、副溶血弧菌、鳗弧菌及美人鱼弧菌为对照菌株, 检测结果均为阴性; 霍乱弧菌人工染菌的8种水产品进行PCR及LAMP检测, 结果均为阳性, 而未染菌组均为阴性; PCR 及LAMP检测霍乱弧菌的方法均具有灵敏度较高、特异性强等优点, 且LAMP检测霍乱弧菌的方法灵敏度是PCR方法的100倍, 更适合于养殖现场检测的推广使用。
关键词:  霍乱弧菌, PCR, LAMP, 特异性, 灵敏性
DOI:10.11693/hyhz201301031031
分类号:
基金项目:江苏省水产三新工程重大项目资助, DY2012-3-7 号; 中央财政支持地方高校发展专项资金资助, CXTD16 号; 江苏高校优势学科建设工程项目资助, 2011
附件
COMPARISON BETWEEN PCR AND LAMP METHODS FOR THE DETECTION OF VIBRIO CHOLERAE ISOLATED FROM DISEASED MISGURNUS ANGUILLICAUDATUS
ZHANG Xiao-Jun, BAI Xue-Song, BI Ke-Ran, XU Jia-Tao, QIN Lei, YAN Bin-Lun
College of Ocean, Key Laboratory of Oceanic Biotechnology of Jiangsu, Huaihai Institute of Technology
Abstract:
The specific primers of polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) were designed based on lolB gene. PCR and LAMP methods for the detection of Vibrio cholerae were established, and their specificity, sensitivity and practical application were compared in this study. The results showed the PCR primers could detect V. choleraeat the lowest level of 4.0×103 CFU/ml using PCR method, the LAMP primers could detect V. choleraeat the lowest level of 4.0×101 CFU/ml within 60min under isothermal condition at 65℃ using the LAMP detection system. The green amplified products were observed directly by naked-eye in the reaction tube by addition of SYBR Green I, and no cross reaction was detected in 4 kinds of control pathogenic bacteria including A. sobria,V. parahaemolyticus,V. anguillarum and V. damsela. The positive reaction was observed in PCR and LAMP detection system for artificial infected aquatic products, and control groups were negative. The studies revealed that they have equal effects between the PCR and LAMP in specificity and actual application, sensitivity level of LAMP is 100 times of the PCR method, and the LAMP method could be useful in the specific and rapid diagnose of the disease caused by V. cholerae in aquaculture.
Key words:  Vibrio cholerae, PCR, LAMP, Specificity, Sensitivity
版权所有 海洋与湖沼 Oceanologia et Limnlolgia Sinica Copyright©2008 All Rights Reserved
主管单位:中国科协技术协会 主办单位:中国海洋湖沼学会
地址:青岛市海军路88号  邮编:266400  电话:0532-82898753  E-mail:ols@qdio.ac.cn
技术支持:北京勤云科技发展有限公司