为了提高深海鲣鱼(Katsuwonus pelamis)干制品的质量,采用低温热泵联合干燥技术,对深海鲣鱼干制品的色差值、复水比、细菌总数、T-VBN值以及能耗值等指标进行分析测定。实验结果表明,低温热泵联合干燥技术较传统单一干燥技术在干燥效果、干燥能耗以及投入设备成本等方面更具有优势。进一步对影响低温热泵干燥技术的因素主要包括填物料量、循环风速、干燥室温度和相对湿度等进行优化。研究结果表明:深海鲣鱼(500g左右)在干燥室相对湿度控制35%、干燥室温度为45℃、装填物料量为8kg、循环风速为2.5m/s时候干燥效果最佳,并且节能效果明显,能耗降低达到35.2%。该成果的成功开发对降低水产品干燥过程中的耗能问题具有促进作用。
关键词:  深海鲣鱼  低温热泵技术  联合干燥  品质分析
DOI:10.11693/hyhz20150200046
分类号:
基金项目:浙江省自然科学基金项目,LY13C00005号;舟山市科技计划项目,2014C41002号,2014C41010号;浙江海洋学院科研启动资助项目,21135012614号,21135013115号。
LOW-TEMPERATURE HEAT-PUMP COMBINED DEHYDRATION FOR SKIPJACK TUNA KATSUWONUS PELAMIS AND THE QUALITY ASSESSMENT
wanghuan,Baidong,xiechao,linlin and huangju
Zhejiang Provincial Key Laboratory of Health Risk Factors for Seafood, College of Food and Medicine, Zhejiang Ocean University,Zhejiang Provincial Key Laboratory of Health Risk Factors for Seafood, College of Food and Medicine, Zhejiang Ocean University,Zhejiang Provincial Key Laboratory of Health Risk Factors for Seafood, College of Food and Medicine, Zhejiang Ocean University,Zhejiang Provincial Key Laboratory of Health Risk Factors for Seafood, College of Food and Medicine, Zhejiang Ocean University,Zhejiang Provincial Key Laboratory of Health Risk Factors for Seafood, College of Food and Medicine, Zhejiang Ocean University
Abstract:
We developed a technology of low-temperature heat-pump combined dehydration for skipjack tuna Katsuwonus pelamis process, for which indices of color difference, rehydration ratio, total number of bacteria, T-VBN (total volatile basic nitrogen) value, and energy cost were assessed. Results show that the technology effectively reduced the energy consumption and equipment costs, and easily to be applied. In our experiment, the optimal conditions included: individual fish weight about 500g, room temperature 55℃, aeration speed 2.5m/s, bulk weight 8kg, and relative humidity in drying chamber 35%, under which electric cost was reduced by 32.4%. This achievement could improve the seafood process and preservation.
Key words:  skipjack tuna Katsuwonus pelamis  low-temperature heat-pump  combined dehydration  quality analysis